EN
10kV/400kW-10000kW Medium Voltage Permanent Magnet Drive
10kV/400kW-10000kW Medium Voltage Permanent Magnet Drive

10kV/400kW-10000kW Medium Voltage Permanent Magnet Drive


Whatever your industry is, Hiconics's medium voltage drive could be an all-rounder to control your standard applications and optimize your processes. Tailor the drive to your specific application by selecting from an extended choice of pre-engineered options. Extensive versatility makes our VFD suitable for operations in different conditions and environments, even hazardous areas. High reliability in your daily business is ensured by the drive's simple design and robust control platform that has proven itself over many years.

Contact us


Products

Technical Parameters of 10kV/400kW-10000kW Medium Voltage Permanent Magnet Drive

VoltageMotor Power(KW)Output Capacity(KVA)ModelWeight
(kg)
Dimension
(W*H*D)
Cabinet Type
10kV315400HPM-1A0-315-1010/02329952350×1400×2000LL1.7
355450HPM-1A0-355-1010/0263025
400500HPM-1A0-400-1010/0313114
450560HPM-1A0-450-1010/0333130
500630HPM-1A0-500-1010/0403160
560700HPM-1A0-560-1010/0423170
630800HPM-1A0-630-1010/0483180
710900HPM-1A0-710-1010/0523200
8001000HPM-1A0-800-1010/0613225
9001150HPM-1A0-900-1010/0653310
10001250HCA-1A0-1000-1010/07745602700×1600×2250LL2.7
11201400HPM-1A0-1120-1010/0864666
12501600HPM-1A0-1250-1010/0964716
14001800HPM-1A0-1400-1010/1044766
16002000HPM-1A0-1600-1010/1154795
18002250HPM-1A0-1800-1010/1304816
20002500HPM-1A0-2000-1010/15477404750×1600×2250LL3.7
22502800HPM-1A0-2250-1010/1658240
25003200HPM-1A0-2500-1010/1928715
28003500HPM-1A0-2800-1010/2059215
32004000HPM-1A0-3200-1010/2439725
36004500HPM-1A0-3600-1010/260128207200×1400/1600×2400LL4.7
40005000HPM-1A0-4000-1010/30413420
45005650HPM-1A0-4500-1010/32514120
50006300HPM-1A0-5000-1010/36414620
55007000HPM-1A0-5500-1010/40014720
More Options

Back


Specification of 10kV/400kW-10000kW Medium Voltage Permanent Magnet Drive

ItemParameters
VFD rated power210~28000kVA※
Rated voltage3.3kV~11kV(-20%~+5%)※(Out of range, special instructions required)
Rated Frequency50Hz/60Hz(-10%~+10%)※
Control Power380VAC, 30kVA
Rated input power factor≥0.96
Effciency>96%
Output frequency range0~80Hz※
Speed accuracy±0.5%(Open loop vector) ±0.1%(close loop vector)
Instantaneous over-current protection150%( Can be customized according to user requirements)
Over capacity120% load for 120s
Torque limitation10%~150%
Analog input3 ways 4~20mA/Excitation feedback 4~20mA(Customized)
Analog output4ways 4~20mA
Host communicationIsolated RS485 interface, ModBus RTU, Profibus DP(optional), Industry Ethernet
Acceleration and deceleration time5s~6000s ( related to load)
DI14 inputs/22 outputs (Output 8 ways can be defined)
Environment temperature-5~+45℃※
Storage/transportation temperature-25~+55℃※
Cooling methordAir forced cooling (AF) / Water cooled (WF)/Air forced water cooled (AFWF)
Humidity<95%, no condensation
Altitude≤1000m, when altitude is higher than 1000m, each 100 meter increasing needs 1%
derating of VFD
DustNon-conductive, no causticity, <6.5mg/dm3※
Protection levelIP30※
Cabinet colorsRAL 7032(customized)



VFD Application Industries and Fields


HIVERT Standard medium voltage VFD series is widely used in various fields in national economy, exported to Europe, Middle East, Southeast Asia etc.. Perfect solutions for soft start, speed adjusting, energy saving and intelligent control of medium voltage AC motors (including synchronous and asynchronous motors) could be supplied to customers. Typical application industries are:


Cement
Application Of VFD In Cement

Kiln draft fan

Kiln gas blower

Separator fan

Kiln head fan

High temperature fan

Cement mill fan

Dust removal fan

Circulating fan

Grate cooler

Raw material mill fan

Raw material mill

Coal mill

Kiln tail fan

Rotating kilntransmission

Compressive force draftfan

Electricity
Application Of VFD In Electricity

Powder exhaust fan

Booster fan

Force draft fan

Induced draft fan

Condensation pump

Slurry pump

Water and energy storage pump Circulating water pump

Boiler (feed) pump

Compressor

Municipal
Application Of VFD In Municipal

Aeration fan

Induced draft fan

Force draft fan

Force pump

Medium water pump

Sewage pump

Hot water circulating pump

Lifting pump

Cleaning water pump

Water supply pump

Metallurgy
Application Of VFD In Metallurgy

Induced draft fan

Secondary de-dusting fan

Force draft fan, Feeding pump

Compressing blower

Blast furnace blower

Blast/ Converter de-dusting fan

Electric furnace de-dusting fan

Sulfur dioxide blower

Slag-flushing pump, Mud pump

De-scaling pump

Water-delivery pump

Phosphorus removal pump

Gas compression pump

Kneading machine

Oxygen compressor

Coal Mines & Minerals
Application Of VFD In Coal Mines & Minerals

BFDS

De-dusting fan

Main fan

Axial flow fan

De-scaling pump

Mud pump

Slurry pump

Clean water pump

Feeding pump

Stirring pump

Agitating pump

Drainage pump

Medium pump

Band conveyor

Kilndrive

Petrochemical
Application Of VFD In Petrochemical

Booster fan

Induced draft fan

Pipeline transportation

pump

Water injection pump

Feed water pump

Submerged pump

Oil transfer pump

Brine pump

Circulating water pump

Compressor

Others
Application Of VFD In Other Industries

Pump test stand

Inverter power supply test stand

Motor test stand

Wind tunnel test

High-quality Variable Frequency Drive

Stable, Intergrated Solution, Alliance

Looking For High-quality Variable Frequency Drive, SVG Generator & Energy Storage System Service?

Related Medium Voltage Drive

Latest News & Blog

MORE +
Types of Energy Storage Systems and Their Application Scenarios
Oct 25-2024
Read More
Power Storage System and Its Application Cases
Oct 22-2024
Read More
+
You are going to jump to the third platform. Do you confirm the jump? It will jump after your confirmation.