Hiconics's CM Low Voltage Drive could realize the improvement of productivity and energy efficiency of your processes, reduce the maintenance costs. Our Low Voltage Drive are widely used in a variety of areas, such as mixers, conveyors, compressors, fans, pumps, centrifuges, as well as process control in industries including material handling, chemical, rubber and plastics, textile, and printing. The drives are easy to select, install, configure, and use, saving considerable time. Our drives are available directly from stock or can be built to order to meet more complex requirements. Our life cycle services will ensure your processes run exactly as you expect.

Contact us


Products

Back


Specification of 3 Phase 220V/0.4-800kW Low Voltage Drive

ItemSpecifications
Main control
functions
Maximum
frequency
Vector control: 0~600Hz
VF control:0~1200Hz
Carrier Frequency1k ~ 15kHz; the carrier frequency will be automatically
adjusted according to the load characteristics.
Input frequency
resolution
Digital setting: 0.01Hz
Analog setting: maximum frequency ×0.1%
Control modeOpen loop vector control ;
V/F control.
Start-up torqueMode G machine: 0.5Hz/180% (open loop vector control)
Mode P machine: 0.5Hz/120% (Open loop vector control)
Speed adjustment
range
1:200(Open loop Vector flux control)
Main control
functions
Stable speed
Precision
Open loop  Vector flux  control:≤±0.5% (rated synchronous
speed)
Stabilization of
speed control
Open loop  Vector flux  control:≤±0.3% (rated synchronous
speed)
Torque response≤40ms(Open magnetic flux vector control)
Overload capacityMode G machine: 150% rated  current 60s; 180% rated current 5s
Mode P machine: 130% rated current 60s; 150% rated current 5s
Torque boostAutomatic torque boost; manual torque boost 0.1% to 30.0%
V/F curveLinear V/F, Multi-point V/F, and Square V/F
Speed-up andStraight line or S curve speed-up and speed-down mode;
four kinds of speed-up and speed-down time;
Speed-down curveSpeed-up and speed-down time ranges from 0.0s
to 3000.0s
DC brakeDC brake frequency: 0.00Hz ~ maximum frequency; brake time: 0.0s ~ 36.0s, and brake current value: 0.0% to 100.0%.
Jog controlJog frequency range:0.00Hz ~ 50.00Hz;
Jog speed-up/speed-down time: 0.0s ~ 3000.0s.
Simple PLC and
multi-speed running
It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDIt is easy to realize process-controlled close loop control system.
(AVR)Automatic
voltage regulation
It can  keep constant output voltage automatically in case of change of mains voltage.
Torque limit and
control
"Shovel" characteristics, automatic limit on the torque on running time, preventing frequent over-current trip; closed loop vector mode can realize the torque control
Customized functionsPeripherals
self-detection upon
power-on
It can  conduct safety detections on  the peripherals upon power-on, including earth and short circuit detections.
Shared DC bus
function
It can realize the function that multiple inverters share the DC bus.
JOG keyProgrammable key: Select the forward and reverse rotations/jog operation command.
Traverse frequency
control
Multiple triangular-wave frequency control function.
Fast current limit
function
With fast current limit algorithm built in to reduce the probability of over-current alarm; to improve the anti-jamming capacity of the whole machine.
Timed controlTiming control function: Setting time range from 0h to 65535h.
Keyboard extension
line standardization
Customers can use standard cable to extend the keyboard
Operation
function
Running command
channel
Three types of channels: operation panel given, control terminal given and serial communication port given. These channels can be switched in various ways.
Frequency sourceTen types of frequency sources in total: digital given, analog voltage given, analog current given, pulse given, and serial port given. It can be switched in various ways.
Auxiliary frequency
source
Ten types of auxiliary frequency sources in total. It can implement micro tuning and synthesis of auxiliary frequency.
Input terminalSeven digital input terminals, and nine terminals in maximum
(AI1, AI2 can be used as DI terminals), it has compatibility to
PNP or NPN input method.
Two analog input terminals, in which AI1 only be used for
voltage input, and AI2 can be used as voltage or current
input. (if expanded- input or output terminal function is
needed, please use HIC580 series.)
Output terminalOne digital output terminal (bipolar output)
Two relay output terminal
Two analog output terminals, with optional 0/4mA to 20mA
or 0/2V to 10V. It can realize the output of set frequency,
output frequency and rotation speed etc.
Display and Keyboard
Operate
LED displayDisplay parameter
LCD displaySelective parts, Chinese/English to suggest the operation
content
LCD Parameter copyUse LCD parameter special copy keyboard can copy the
parameter quickly
Key lock and
function choose
Lock part of the keyboard or the whole keyboard, definite the
function range of some keys to avoid mis-operation.
Protection
and select
accessories
protection functionShort circuit detective of power-on motor, input and output
open-phase protection, over-current protection, overvoltage
protection, under-voltage protection, over-heat protection,
over-load protection etc.
Selective accessoriesLCD operation panel, brake group etc.
EnvironmentSuitable placeIndoor environment which is against from direct sunlight,
dust, corrosive gas, combustible gas, oil mist, vapor, water
drop and salt.
AltitudeLess than 1000m
Ambient
Temperature
-10℃ ~ +50℃ (derating is required if the natural temperature
range is 40℃ ~ 50℃)
HumidityLess than 95%RH, no condensing water drops
VibrationLess than 5.9m/ s2 (0.6g)
Storage temperature-20℃ ~ +60℃
Class of pollution2





VFD Application Industries and Fields


HIVERT Standard medium voltage VFD series is widely used in various fields in national economy, exported to Europe, Middle East, Southeast Asia etc.. Perfect solutions for soft start, speed adjusting, energy saving and intelligent control of medium voltage AC motors (including synchronous and asynchronous motors) could be supplied to customers. Typical application industries are:


Cement
Application Of VFD In Cement

Kiln draft fan

Kiln gas blower

Separator fan

Kiln head fan

High temperature fan

Cement mill fan

Dust removal fan

Circulating fan

Grate cooler

Raw material mill fan

Raw material mill

Coal mill

Kiln tail fan

Rotating kilntransmission

Compressive force draftfan

Electricity
Application Of VFD In Electricity

Powder exhaust fan

Booster fan

Force draft fan

Induced draft fan

Condensation pump

Slurry pump

Water and energy storage pump Circulating water pump

Boiler (feed) pump

Compressor

Municipal
Application Of VFD In Municipal

Aeration fan

Induced draft fan

Force draft fan

Force pump

Medium water pump

Sewage pump

Hot water circulating pump

Lifting pump

Cleaning water pump

Water supply pump

Metallurgy
Application Of VFD In Metallurgy

Induced draft fan

Secondary de-dusting fan

Force draft fan, Feeding pump

Compressing blower

Blast furnace blower

Blast/ Converter de-dusting fan

Electric furnace de-dusting fan

Sulfur dioxide blower

Slag-flushing pump, Mud pump

De-scaling pump

Water-delivery pump

Phosphorus removal pump

Gas compression pump

Kneading machine

Oxygen compressor

Coal Mines & Minerals
Application Of VFD In Coal Mines & Minerals

BFDS

De-dusting fan

Main fan

Axial flow fan

De-scaling pump

Mud pump

Slurry pump

Clean water pump

Feeding pump

Stirring pump

Agitating pump

Drainage pump

Medium pump

Band conveyor

Kilndrive

Petrochemical
Application Of VFD In Petrochemical

Booster fan

Induced draft fan

Pipeline transportation

pump

Water injection pump

Feed water pump

Submerged pump

Oil transfer pump

Brine pump

Circulating water pump

Compressor

Others
Application Of VFD In Other Industries

Pump test stand

Inverter power supply test stand

Motor test stand

Wind tunnel test

High-quality Variable Frequency Drive

Stable, Intergrated Solution, Alliance

Looking For High-quality Variable Frequency Drive, SVG Generator & Energy Storage System Service?

Related Low Voltage Drive

Latest News & Blog

MORE +
Types of Energy Storage Systems and Their Application Scenarios
Oct 25-2024
Read More
Power Storage System and Its Application Cases
Oct 22-2024
Read More
+
You are going to jump to the third platform. Do you confirm the jump? It will jump after your confirmation.