More compact than the last generation
Enable 16-speed switching through external terminals
Protection rating
HCM100 is a general-purpose compact VFD with high rellablity and rich hardware and software configurations. It is compact, user-friendly, and relable, making it widely applicable in food and beverage, logistics packaging, spin, and woodworking machinery industries.
High power density with a compact design, supports seamless installation on guide rails or wall mounting; 50% more compact than the last generation, saving panel space and making on-site installation more flexible;
1) Supports external operating panel options. Supports one-click parameter download and quick copying;
2) Supports host computer monitoring software for real-time error and operating state monitoring. Simple and user-friendly for startup and commissioning;
3) Supports networking design, multi-speed running, energy conservation modes, sleep mode during idle states, and other industry-specifilc features, making it sultable for various industrlal appllcations such as fans and pumps.
1) Supports external operating panel options. Supports one-click parameter download and qulck copying:
2) Supports host computer monitoring software for real-time error and operating state monitoring. Simple and user-friendly for startup and commissioning;
3) Supports networking design, multi-speed running,energy conservation modes, sleep mode during idle states, and otherindustry-specific features, making it suitable for various industrial applications such as fans and pumps.
Item | Introduction | ||||||||||||||||
Acceleration and deceleration curve | Straight line, S-curve, power function with an exponent of 1.5 curve, and quadratic curve (with initial arc adjustable separately) Automatic acceleration and deceleration curves | ||||||||||||||||
Built-in PID | Built-in PID enables process control on specific occasions | ||||||||||||||||
Run command channels | Three channels: operating panel, external terminals, communication setting (switchable via parameters) | ||||||||||||||||
Frequency hopping function | Skip certain frequency bands to avoid resonance points | ||||||||||||||||
Dynamic braking | Reduce bus voltage swell through energy consumption | ||||||||||||||||
Multi-speed running | Enable16-speed switching through external terminals | ||||||||||||||||
Automatic voltage regulation | Automatically maintains a constant voltage output when the grid voltage changes | ||||||||||||||||
Overvoltage, overcurrent, and stall prevention | Automatically limit current and voltage during operation; in this way, frequent overcurrent, overvoltage, and trips are prevented | ||||||||||||||||
Fast current limiting function | Minimise overcurrent to stabilise VFDs under extreme conditions | ||||||||||||||||
Energy-saving mode | Automatically limit current and voltage during operation; in this way, frequent overcurrent, overvoltage, and trips are prevented | ||||||||||||||||
Momentary stop non-stop | Effective methods for compensating voltage drops during sudden power outages. VFD remains uninterrupted for short durations |
Item | Specification | ||||||||||||||||
Use place | Indoor, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapour, dripping water or salt, etc.; Below an altitude of 1000m, no derating is required. Above 1000m, derating is required | ||||||||||||||||
Built-in PID | -10℃~+40℃ (excluding models with free cooling, installed closely side by side, with an upper limit of the operating temperature of 40℃; Operation exceeding 40℃ requires derating, with a maximum operating temperature of 50℃) | ||||||||||||||||
Storage temperature | -20℃~+60℃ | ||||||||||||||||
Humidity | <95% (RH), w/o water droplets | ||||||||||||||||
Vibration | <5.9m/s2 (0.6g) | ||||||||||||||||
Protection rating | IP20 | ||||||||||||||||
Degree of environmental pollution | 2 | ||||||||||||||||
Cooling method | Forced air cooling |
Item | Specification | ||||
Control mode | V/F control | ||||
Frequency setting/output frequency resolution | Panel control: Below 1OHz: 0.01Hz; above 10Hz: 0.1Hz Communication control: 0.01HzAnalogue setting: Maximum frequency×±0.1% | ||||
Torque characteristics | Starting torquemeets 150% of rated to rque at 5.0Hz | ||||
Overload capacity | 150% of rated output current for 60 seconds, 180%for 2 seconds | ||||
Prohibit frequency setting | 3-point setting from 0.1-599.0Hz | ||||
Acceleration and deceleration time | 0.1-600 seconds (4-segment acceleration/deceleration time canbe set separately) | ||||
Stall prevention | Motor load characteristics can be set to 20-200% of the drive's ratedcurrent | ||||
DC braking | The operation can be adjusted from 0.1-599.0 Hz during a stop, Braking current: O-100% of rated current; starting time: 0-60 seconds, and stopping time: 0-60 seconds | ||||
V/F curve | Arbitrary V/F curve setting | ||||
Frequency Setting Signal | External signal | External terminals: UP/DOWN frequency, jog operation, AVI/ACI: O-+10VDC/4-20mA Serial communication port: Standard models support RS485, while extended models support CANopen | |||
Operation Signal setting | Panel operation | Set by RUN and STOP keys | |||
External signal | MI1, MI2, MI3 two/three-cable control forjog operation and the serlal communication port (RS485) | ||||
Input terminal functions | 16-speed settings (including main speed) with default speed switching. commands to disable acceleration and deceleration, 4-segment acceleration and deceleration switching, external counting, drive reset, increment/decrement frequency terminal settings and jog operation | ||||
Output terminal functions | Indication in operation, frequency reach indication, zero speed indication, counter reach indication, fault indication overheat warning, and emergency stop | ||||
Communication/bus | HCM100A supports RS485 communication, while HCM100Bsupports CAN open | ||||
Analogue quantity inputs | One AI | ||||
Digital input | Four DI | ||||
Digital operator panel | One normally-open relay output | ||||
Including 6 function keys, a 4-digit 7-segment LED display, and 4 status LED indicators, the panel allowsfor frequency setting and displays actual output frequency and current. It also supports us-er-defined units, parameter browsing, settings modification, parameter lock function, and faultdisplay. Operations such as start, stop, reset, forward, and reverse can be performed on this device | |||||
Background software | Supports VFD parameter operation and virtual oscilloscope function; Graphical monitoring of internal VFD status isrealisedvia a virtual oscilloscope: | ||||
Digital operator panel | Including undervoltage, overvoltage, overcurrent, short circuit before an operation, GBT overtemperature, VFD overload, motor overload, detection line abnormality, PID disconnection, parameter reading abnormality, parameter password error, communication abnormality, communication timeout, DEB abnormality, overslip, input phase loss, output phase loss, E-stop of external terminals, external terminal abnormality, external interrupt,etc. |