What is the Difference between Soft Starter and VFD

Mar 07 , 2023

1. what is the difference between soft starter and VFD: function and cost

VFD can provide more flexible functions than soft starters, including digital diagnostic information. With VFD, you can use a variety of communication types to receive feedback, from hard-wired I/O points (if you only need minimal feedback) to Ethernet (if you want all data from the drive available to the controller).


What is the difference between soft starter and VFD? In many applications, it's necessary to continuously adjust the speed of a motor, making a drive a good solution. However, in many applications, the drive is used only to start and stop the motor, even if continuous speed regulation is not needed. This would create an unnecessarily expensive solution compared to a soft starter. In constant speed applications, a soft starter is still the most economical solution. However, while VFDs offered by the professional VFD manufacturer may initially be more expensive, they can significantly save energy, reducing operating costs over the equipment's life cycle, and therefore reducing total cost of ownership.


2. what is the difference between soft starter and VFD: market size

What is the difference between soft starter and VFD? A reliable frequency inverter supplier can provide you with a clear understanding of the primary difference between them. Compared to soft starters, the market size for VFDs is extremely large. Most motors require speed control, making a VFD a perfect solution. By 2023, the global VFD market is expected to reach a market size of $27.57 billion. By 2023, the global market for soft starters is expected to reach $2.0 billion.


The drive has a larger physical size and requires more space. Soft starters are typically the solution for applications where space is a consideration, as they typically take up less space than VFDs.


As the drive changes frequency and generates sine waves, it will cause harmonics on the network. Additional filtering and shielded cables are used to minimize these issues, but harmonics are typically not eliminated. Soft starters do use bypass contacts to switch to line-to-line operation. Therefore, during line-to-line operation it will be a linear load. This means it won't inject harmful harmonic distortion into your factory's AC grid. The drive is also much heavier than a soft starter. This makes it less ideal for solutions where weight is important, such as on heavy ships.


3. What is the difference between soft starter and VFD: forward and reverse operation

What is the difference between soft starter and VFD? By itself, a soft starter cannot run a motor at full speed in reverse. However, forward and reverse operation can be accomplished by arranging for forward and reverse contactors. Some soft starters also offer partial speed functions to allow the motor to run forward or reverse at a low speed without needing reversing contactors. However, reverse operation is limited to short periods of time at a fixed low speed. On the other hand, VFDs can run in forward and reverse.